24/7 alarm & service line: 0544 774 73 37
Ecoolution Engineering & Automation

Refrigeration automation and 24/7 remote monitoring solutions

From the equipment on site to the 24/7 monitoring centre: end-to-end solutions for preventive maintenance, leak prevention, low-GWP systems, F-Gas compliance and grant-funded projects.

HOW SMART REFRIGERATION WORKS

One chain, from the controller on site to the monitoring centre.

We don't just collect data and send reports. We install the refrigeration system, make it smart and step in on site when needed.

  1. 01
    SITE

    Smart control

    Controllers, sensors and energy meters are installed. The system adjusts itself to demand.

    Room controller+2.4 °C
    Suction pressure2.6 bar
    Energy meter38.4 kW
  2. 02
    CONNECTION

    SCADA & cloud

    All sites come together on one platform. Temperature, alarm, energy and equipment data flow live.

    ModbusBACnet4G / VPN
    Connection active10 s
  3. 03
    MONITORING

    24/7 expert monitoring

    Alarms reach our monitoring team. We prioritise them, diagnose remotely and respond immediately if needed.

    Cold room 2 · +7.8 °C
    Team called02:17
    Remote response02:24
  4. 04
    RESULT

    Action & reporting

    Instant alerts, service dispatch, energy and carbon reports. The system runs a little more efficiently every month.

    Monthly energySAMPLE
    ReportPDF · 1st of every month
PREVENTIVE MONITORING

We see the fault before the alarm goes off.

A conventional alarm goes off when the temperature crosses a limit, and by then the product is already at risk. We watch pressure, run-time and temperature trends to catch deterioration days in advance and fix the fault before an alarm is ever raised.

Dirty condenser (rising discharge pressure)
Falling refrigerant charge (superheat and subcooling trend)
Longer defrost times and icing
Compressor short cycling
Rising duty cycle and energy deviation
Doors left open and operating mistakes
Discharge pressure trend · Rack ASAMPLE
Conventional alarm thresholdPreventive warning thresholdEarly response → back to normalWithout a response
The team is sent to site at the preventive warning, before the value reaches the conventional alarm threshold. Product is never at risk and there is no emergency call-out cost.

Gas leak prevention

We catch the leak the moment it starts, not on the service invoice.

· Continuous charge monitoring via liquid level and subcooling trends· Installation of room gas detectors and leak detection systems· Periodic leak checks and digital records· Leak location, repair and recommissioning

System optimisation

More stable cooling from the same system with less energy.

· Floating suction and floating condensing pressure· Defrost on demand and night setpoint management· Electronic expansion valve and fan settings· Compressor sequencing and capacity control
LOW-GWP SYSTEM SOLUTIONS

We don't wait for the bans; we solve it today.

We design and commission systems that run on natural refrigerants. Low-carbon cooling that already meets the requirements of 2031 and beyond.

R717GWP 0

Ammonia system commissioning

Automation, safety scenarios, gas detector integration and commissioning at industrial ammonia plants.

R744GWP 1

CO₂ system integration

Automation, high-pressure control, monitoring and commissioning for CO₂ and NH₃/CO₂ cascade systems.

R290GWP 3

Propane chiller start-up

Commissioning propane chiller groups with control, capacity management, safety equipment and monitoring infrastructure.

SupermarketLow charge

Display cases fed by a chiller

In supermarkets, we run display cases on a low-GWP chiller and a secondary fluid loop. The refrigerant stays in the machine room; no refrigerant line enters the sales floor.

SYSTEM ARCHITECTURE

Where is the refrigerant, and where does the cooling go?

ROOFR290 chillersealed unit · limited chargeGWP 31PLANT ROOMSALES FLOORPump set3glycol / water lineDairy aisleDeliFruit & vegCold room24Ecoolution 24/7 monitoringtemperature · pressure · flow · energy · alarms
  1. 1The refrigerant stays in the sealed unit. Propane (R290) is inside the chiller unit on the roof; the charge is limited.
  2. 2No refrigerant on the sales floor. Only glycol / water goes to the cases and the cold room.
  3. 3Pump and valve control. Each case is fed by a motorised valve with only what it needs; a standby pump is ready.
  4. 4Every point is monitored. Case, pump and chiller sensors connect to our monitoring layer; our team steps in if anything drifts.

GWP values: IPCC AR4. Ban dates: Turkish Regulation on Fluorinated Greenhouse Gases, Official Gazette 15.10.2024, No. 32693. Diagrams show a sample system layout.

F-Gas Regulation

Is your R404A system ready for 2027?

The Regulation on Fluorinated Greenhouse Gases, in force in Türkiye since 15 October 2024, set the ban schedule for high-GWP gases. Businesses that plan today will save on both gas and service costs tomorrow.

Free F-Gas preliminary assessment
  1. 15 October 2024Regulation in forceHFC quotas, equipment registration in EKOMVET and mandatory periodic leak checks based on CO₂e quantity.
  2. 1 January 2027Ban on new equipment with GWP ≥ 2500New stationary refrigeration equipment and hermetic commercial cabinets using gases such as R404A and R507A can no longer be placed on the market.
  3. 1 January 2031GWP ≥ 150 in central systemsGWP ≥ 150 is banned in new multi-compressor commercial systems of 40 kW and above. Equipment of 40 t CO₂e and above can no longer be serviced with gas of GWP ≥ 2500.
  4. 1 January 2033Transition exemptions endThe exemption for servicing with reclaimed gas, or gas recovered from the same equipment, ends.

Leak check frequency

5 – 50 t CO₂eEvery 12 months (24 months with a detection system)
50 – 500 t CO₂eEvery 6 months (12 months with a detection system)
500 t CO₂e and aboveLeak detection system mandatory

Example: a central supermarket system holding 100 kg of R404A comes to about 392 t CO₂e. A leak detection system halves the check frequency.

Inventory and CO₂e calculationWe list the gas type, charge and obligations for all your equipment.
Record and check trackingWe schedule periodic checks and keep records ready for EKOMVET.
Leak detection systemDetectors and continuous monitoring for both compliance and early warning.
Low-GWP transition planA conversion that suits your existing system, or CO₂ and propane options for new investments.
Read the full roadmap article

Source: Turkish Regulation on Fluorinated Greenhouse Gases, Official Gazette 15.10.2024, No. 32693. This is a summary; the text of the regulation applies for exemptions and details.

Grants and state-supported investments

Let's build your grant-funded cold store to spec, and smart.

For cold storage investments backed by rural development, TKDK and development agency support, we take on the refrigeration automation, monitoring and commissioning. We work with your project consultant and deliver every technical document needed for inspections and progress payments.

Room-by-room SCADA screen of a cold storage facility owned by an agricultural development cooperative
Agricultural development cooperative cold store · Room-by-room temperature and humidity monitoring
MINISTRY OF AGRICULTURE AND FORESTRYRural Development Investments (KKYDP)Cold stores are among the topics supported under product processing investments. The grant rate ranges from 50% to 70% depending on the applicant and the project.
TKDK · IPARDEU-funded rural developmentCold storage investments in fruit, vegetables and food processing in programme provinces. A technical project and compliance with EU standards are required.
AGENCIES · KOSGEBDevelopment agency and KOSGEB supportSupport for machinery, equipment and energy efficiency investments through periodic calls. Call conditions vary by region and period.

What we do for grant-funded businesses

01Quote and technical specificationAn itemised quote and equipment list that fits your grant file.
02Installation and commissioningInstallation of the automation, panels and monitoring infrastructure, plus test and commissioning reports.
03Inspection and progress payment documentsInstallation report with photos, serial number list and technical data sheets.
04Monitoring that protects your investment24/7 monitoring reduces the risk of product loss and gives cooperative members room-by-room reports.

Grant rates and conditions change with each call; always check the current announcements of the relevant institution.

SOLUTIONS

From project to service, one team.

You can start with a single service and expand as you need. Whichever you choose, you deal with the same team.

24/7 REMOTE ALARM MONITORING

The 3 a.m. alarm comes to us.

Alarms from your stores and warehouses reach our monitoring team first. If it can be fixed remotely, we fix it; if not, we call you and the service team and follow up until the alarm is closed.

  • Alarm prioritisation and remote diagnosis
  • Notifications by phone, SMS and WhatsApp
  • Every alarm on record: what happened, who responded, how long it took
Get a quote
Cold room 2 · +7.8 °C
Temperature rising
02:14
Monitoring team
Door left open, store called
02:17
Back to normal
No product loss
02:41
SAMPLE ALARM FLOW
ENERGY & CARBON MONITORING

See your energy bill equipment by equipment.

We measure how much each store, each rack and each hour consumes. We show savings with meter data, not estimates.

  • kWh, ₺ and t CO₂e per site and per unit
  • Spotting deviations caused by night load, doors and defrost
  • Monthly report and comparison between branches
Get a quote
Energy and carbon monitoring screen: daily consumption, consumption breakdown, load profile and site comparison
REFRIGERATION AUTOMATION

Prevent product loss.

Display cases, cold rooms and compressor racks run at the right temperature without using more energy than they need.

  • Room controllers and electronic expansion valves
  • Defrost on demand and night mode
  • Floating suction and condensing pressure
Get a quote
SCADA & BMS

Run the whole facility from one screen.

Refrigeration, HVAC, fire pumps and energy points on the layout of your own facility.

  • Custom mimic screens for your site
  • Trends, alarm history and reports
  • Access from web and mobile
Get a quote
PREVENTIVE MAINTENANCE & LEAK PREVENTION

Catch the fault before the alarm.

We spot wear early in pressure and run-time trends, so the team goes out on a planned visit, not an emergency call.

  • Trend-based early warning
  • Gas leak detection and repair
  • Planned maintenance instead of emergency call-outs
Get a quote
INSTALLATION, SERVICE & COMMISSIONING

The team that installs it looks after it.

Our own team handles everything from installation to commissioning. The same team takes care of service and maintenance afterwards.

  • Panels, cabling and site installation
  • Parameter setup, testing and commissioning
  • Periodic maintenance contract
Get a quote
CUSTOM SOFTWARE

For jobs that don't fit an off-the-shelf package.

We write control logic, integrations and report screens specific to your process.

  • Process-specific control algorithms
  • Data integration with your existing systems
  • KPI and report screens built for you
Get a quote
F-GAS COMPLIANCE SERVICES

Be ready for the 2027 and 2031 deadlines.

We take inventory of your refrigerants and make your obligations and transition options clear.

  • Inventory and CO₂e calculation
  • Leak check schedule and EKOMVET records
  • Low-GWP transition plan
Free preliminary assessment

Let's make your system smart together.

With a free site survey, let's find out together where you are losing energy, product and service costs.